or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
BANNER®
Banner Engineering Q50BUQ Q50 Measurement Sensor, Rectangle Shape, 100 to 400 mm Sensing, Infrared Sensing Beam
BANNER®
Banner Engineering Q50BUQ Q50 Measurement Sensor, Rectangle Shape, 100 to 400 mm Sensing, Infrared Sensing Beam
SKU189244
MFGR #Q50BUQ
$/ea
Banner Engineering Measurement Sensor, Series: Q50, Rectangle, Proximity/Triangulation Sensing Method, 100 to 400 mm Sensing Range, Infrared Sensing Beam, 4 ms Response, 15 to 30 VDC, 70 mA, Cable, LED Light Source, 10 to 60 Hz, NEMA 6/IP67, -10 to 50 deg C Operating, Environmental Conditions: 90% at 50 deg C Non-Condensing Maximum Relative Humidity
Banner Engineering Measurement Sensor, Series: Q50, Rectangle, Proximity/Triangulation Sensing Method, 100 to 400 mm Sensing Range, Infrared Sensing Beam, 4 ms Response, 15 to 30 VDC, 70 mA, Cable, LED Light Source, 10 to 60 Hz, NEMA 6/IP67, -10 to 50 deg C Operating, Environmental Conditions: 90% at 50 deg C Non-Condensing Maximum Relative Humidity
Amperage Rating 70 mA Catalog Number Q50BUQ Connection Type Cable Country of Origin USA Enclosure Type NEMA 6/IP67 Environmental Conditions 90% at 50 deg C Non-Condensing Maximum Relative Humidity Gross Weight Per Pack 1 lb Light Source LED Operating Temperature -10 to 50 °C Sensing Method Proximity/Triangulation Series Q50 Standards CE Marked UNSPSC 39121528 UPC 11 66248863872 UPC 12 66248863872 Vibration 10 to 60 Hz Voltage Rating 15 to 30 VDC Stock Status NONSTOCK Brand Banner® Manufacturer Banner Engineering Corp. Response Time 4 ms Sensing Beam Infrared Sensing Range 100 to 400 mm Shape Rectangular Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments ; Teach a sensing window and position, or a set-point threshold centered within a 100 MM window ; Sensor linearity is better than 3 MM ; Patented scalable analog output (U.S. patent #6,122,039) automatically distributes the output signal over the width of the programmed sensing window ; Analog output slope can be either positive or negative, depending upon which window limit is programmed first ; Two bicolor status LEDs ; Rugged construction withstands demanding sensing environments; rated IEC IP67, NEMA 6 ; Protected against reverse polarity and transient over voltages ; Protected against short circuit conditions ; M3 hardware is included ; Minimum taught window: Target distance at 300 MM - 50 MM window, target distance at 125 MM - 10 MM window ; Resolution: 200 MM target distance, 1 MM slow 0.25 mm per deg C from 0 to 50 deg C, 0.35 mm per deg C from -10 to 55 deg C temperature effect 15 ms warm-up time 880 nm Infrared LED sensing beam Acrylic window Rectangular housing style ABS/Polycarbonate primary housing material Teach button adjustments Protected against reverse polarity and transient overvoltage's 90% at 55 deg C non-condensing relative humidity
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Amperage Rating | 70 mA |
| Catalog Number | Q50BUQ |
| Connection Type | Cable |
| Country of Origin | USA |
| Enclosure Type | NEMA 6/IP67 |
| Environmental Conditions | 90% at 50 deg C Non-Condensing Maximum Relative Humidity |
| Gross Weight Per Pack | 1 lb |
| Light Source | LED |
| Operating Temperature | -10 to 50 °C |
| Sensing Method | Proximity/Triangulation |
| Series | Q50 |
| Standards | CE Marked |
| UNSPSC | 39121528 |
| UPC 11 | 66248863872 |
| UPC 12 | 66248863872 |
| Vibration | 10 to 60 Hz |
| Voltage Rating | 15 to 30 VDC |
| Stock Status | NONSTOCK |
| Brand | Banner® |
| Manufacturer | Banner Engineering Corp. |
| Response Time | 4 ms |
| Sensing Beam | Infrared |
| Sensing Range | 100 to 400 mm |
| Shape | Rectangular |
| Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments ; Teach a sensing window and position, or a set-point threshold centered within a 100 MM window ; Sensor linearity is better than 3 MM ; Patented scalable analog output (U.S. patent #6,122,039) automatically distributes the output signal over the width of the programmed sensing window ; Analog output slope can be either positive or negative, depending upon which window limit is programmed first ; Two bicolor status LEDs ; Rugged construction withstands demanding sensing environments; rated IEC IP67, NEMA 6 ; Protected against reverse polarity and transient over voltages ; Protected against short circuit conditions ; M3 hardware is included ; Minimum taught window: Target distance at 300 MM - 50 MM window, target distance at 125 MM - 10 MM window ; Resolution: 200 MM target distance, 1 MM slow |
| 0.25 mm per deg C from 0 to 50 deg C, 0.35 mm per deg C from -10 to 55 deg C temperature effect |
| 15 ms warm-up time |
| 880 nm Infrared LED sensing beam |
| Acrylic window |
| Rectangular housing style |
| ABS/Polycarbonate primary housing material |
| Teach button adjustments |
| Protected against reverse polarity and transient overvoltage's |
| 90% at 55 deg C non-condensing relative humidity |